300A, 21kV, SVR Unit, 35% Boosting Capability
(MV SVR U.S. Patent Number 6,137,277)

The MV SVR boosts the whole-facility load voltage during source voltage sags caused by faults in the utility distribution grid or in the transmission system. The load voltage boost is performed within quarter to half cycle enabling even the most sensitive facility equipment to ride-through sag events without operational disruptions.

SatCon's patented MV SVR substantially increases reliability of electric power delivered to your facility load bus. The MV SVR mitigates voltage sags at minimal capital and operating costs by providing an improved level of power quality without the addition of any expensive energy storage device.

 

Ratings
Continuous Current (CC) Rating:

100 A through 1,200 A

Short-Circuit Current, 1 second: Up to 12 kA RMS Sym
Nominal System Voltage Range: 3.3 kV through 35 kV
Frequency: 50 Hz or 60Hz
Lightning Impulse Basic Insulation Level, BIL: Up to 150 kV
Voltage Sag Rebuild Capability
Maximum Inserted Voltage: 35% - 40% of nominal voltage
Source Voltage Compensated: Beyond 90%
Maximum Sag Rebuild Time: ½ cycle (8.33 ms for 60 Hz)
Other SVR Unit Technical Data
Minimum Efficiency at > 75% of the CC Rating: 99.7% (3 MVA minimum load)
Load Power Factor Range: 0.75 inductive to 0.75 capacitive
Ambient Temperature Range: -10°C to 40°C standard
Ambient Humidity Range: 0-95% RH non-condensing
Ambient Electro-Magnetic Compatibility (EMC): Select IEEE, IEC, and FCC Std.
MV SVR Features
Benefits to Automated Facility Operators
Reliable Voltage Sag Ride Through Meets the ITI (CBEMA) voltage tolerance curve requirements for voltage sags up to 50% of nominal and duration up to 10 seconds
No Energy Storage Used
Power to compensate for the voltage sag is accomplished by drawing additional current from the sagged utility source
High Efficiency - Low Operating Costs 99.7% for facility loads of 8 MVA and up, no additional heat removal air conditioning (A/C) is required
Application Specific Engineered Units
Units engineered to meet site specific requirements; load size, system voltage, fault currents, ambient T & H extremes
Environmentally Friendly
The MV SVR design utilizes dry-type transformers and power electronics ambient air cooled

 

When to Use an MV SVR

The MV SVR is designed to provide low cost alternative to expensive voltage regulators requiring energy storage. As shown in summary of an EPRI survey of power quality disturbances for an average site, figure 1, the vast majority of voltage sags that results in loss of a process critical load are in the 50 to 90% range of nominal voltage and up to 10 seconds of duration. The MV SVR fully compensates for these sag levels preventing the majority of typical facility downtimes to provide for a quick payback and for high return on investment solution.

Performance:

For source voltage sag compensation, SVR-D provides a more reliable and more robust performance than any complex power inverter or low reliability battery based alternative custom power device solution or Dynamic Voltage Restorer (DVR).


Cost:

Installed unit cost and required land footprint of STS-D is about a third of the cost and of the footprint of the equivalent inverter based DVR size. The SVR-D has significantly lower operation and maintenance cost when compared with DVR due to lower losses (0.3% for SVR vs. 2.0% for DVR), no air conditioning and energy storage requirements.

Design:

The SVR-D design is based on specification inputs of a major North American utility and is fully verified through a comprehensive set of high voltage, high current, environmental and EMI / EMC compatibility design tests for utility acceptance.

Environment:

SVR-D does not include environmentally hazardous transformer oil or energy storage battery. In addition air conditioning equipment is not required for wasted energy removal because of its high efficiency operation.

 

 